Spray tower : ウィキペディア英語版
Spray tower

A spray tower (or spray column or spray chamber) is gas-liquid contactor used to achieve the mass and heat transfer between a continuous gas phase (that can contain dispersed solid particles) and a dispersed liquid phase. It consists of empty cylindrical vessel made of steel or plastic and nozzles that spray liquid into the vessel. The inlet gas stream usually enters the bottom of the tower and moves upward, while liquid is sprayed downward from one or more levels. This flow of inlet gas and liquid in the opposite direction is called countercurrent flow.
This type of technology can be used for example as a wet scrubber for air pollution control. Countercurrent flow exposes the outlet gas with the lowest pollutant concentration to the freshest scrubbing liquid.
Many nozzles are placed across the tower at different heights to spray all of the gas as it moves up through the tower. The reasons for using many nozzles is to maximize the number of fine droplets impacting the pollutant particles and to provide a large surface area for absorbing gas.
Theoretically, the smaller the droplets formed, the higher the collection efficiency achieved for both gaseous and particulate pollutants. However, the liquid droplets must be large enough to not be carried out of the scrubber by the scrubbed outlet gas stream. Therefore, spray towers use nozzles to produce droplets that are usually 500–1000 µm in diameter. Although small in size, these droplets are large compared to those created in the venturi scrubbers that are 10–50 µm in size. The gas velocity is kept low, from 0.3 to 1.2 m/s (1–4 ft/s) to prevent excess droplets from being carried out of the tower.
In order to maintain low gas velocities, spray towers must be larger than other scrubbers that handle similar gas stream flow rates. Another problem occurring in spray towers is that after the droplets fall short distances, they tend to agglomerate or hit the walls of the tower. Consequently, the total liquid surface area for contact is reduced, reducing the collection efficiency of the scrubber.
In addition to a countercurrent-flow configuration, the flow in spray towers can be either a cocurrent or crosscurrent in configuration.
In cocurrent-flow spray towers, the inlet gas and liquid flow in the same direction. Because the gas stream does not "push" against the liquid sprays, the gas velocities through the vessels are higher than in countercurrent-flow spray towers. Consequently, cocurrent-flow spray towers are smaller than countercurrent-flow spray towers treating the same amount of exhaust flow. In crosscurrent-flow spray towers, also called horizontal-spray scrubbers, the gas and liquid flow in directions perpendicular to each other.
In this vessel, the gas flows horizontally through a number of spray sections. The amount and quality of liquid sprayed in each section can be varied, usually with the cleanest liquid (if recycled liquid is used) sprayed in the last set of sprays.
==Particle collection==
Spray towers are low energy scrubbers. Contacting power is much lower than in venturi scrubbers, and the pressure drops across such systems are generally less than 2.5 cm (1 in) of water. The collection efficiency for small particles is correspondingly lower than in more energy-intensive devices. They are adequate for the collection of coarse particles larger than 10–25 µm in diameter, although with increased liquid inlet nozzle pressures, particles with diameters of 2.0 µm can be collected.
Smaller droplets can be formed by higher liquid pressures at the nozzle. The highest collection efficiencies are achieved when small droplets are produced and the difference between the velocity of the droplet and the velocity of the upward-moving particles is high. Small droplets, however, have small settling velocities, so there is an optimum range of droplet sizes for scrubbers that work by this mechanism.
This range of droplet sizes is between 500 and 1,000 µm for gravity-spray (counter current) towers.〔Stairmand 1956〕 The injection of water at very high pressures – 2070–3100 kPa (300–450 psi) – creates a fog of very fine droplets. Higher particle-collection efficiencies can be achieved in such cases since collection mechanisms other than inertial impaction occur.〔Bethea, R. M. 1978. Air Pollution Control Technology. New York: Van Nostrand Reinhold.〕 However, these spray nozzles may use more power to form droplets than would a venturi operating at the same collection efficiency.

抄文引用元・出典: フリー百科事典『 ウィキペディア(Wikipedia)